Fuel Tech Experts
  • Articles
    • Biodiesel & Biofuels
    • Car Emissions
    • Carbon Cleaning
    • Cetane Boosters & 2-EHN
    • DPF Cleaning & Maintenance
    • EGR Cleaning & Maintenance
    • Engine Cleaning & Flushing
    • Engine Oils
    • Engine Tuning & Mapping
    • Fleet & Commercial Solutions
    • Fuel Additives
    • Fuel Quality
    • Fuel Saving
    • Fuel System Cleaning
    • Hybrids
    • MAF & Air Intake Cleaning
    • Misfuelling Devices
    • Octane Boosters
    • Oil Additives
    • Race Fuel
    • Reducing Emissions
    • TFSI Direct Injection Carbon
    • Turbo Cleaning & Maintenance
    • Waterless Engine Coolant
  • Reviews
    • Reviews UK
    • Reviews USA
  • FAQ
    • Carbon Cleaning
    • Cetane/2-EHN
    • Diesel Cleaners
    • Diesel Particulate Filters (DPF)
    • E10 Petrol
    • EGR Valves
    • Engine Break-in
    • Engine Flush
    • Exhaust Emissions
    • Friction Modifiers
    • Fuel Consumption
    • MAF Sensors
    • Oil Additives
  • Tools
    • 2-EHN Cetane Calculator
  • About Us
  • Collaborate
An image of Alex
  • Site banner
  • Try our new cetane calculator

Tag Archives: cetane measurement

Cetane/2-EHN

How is cetane number measured (CFR method, ASTM, etc.)?

July 15, 2025 Alex Leave a comment

Quick answer

Traditionally, a special test engine (CFR engine) is used, comparing the diesel’s ignition to reference fuels. Other ASTM methods calculate an estimate using fuel properties (e.g., density, distillation).

Detailed answer

Measuring the cetane number involves both direct engine testing and more convenient calculated methods. The CFR (Cooperative Fuel Research) engine test is considered the gold standard: technicians run the fuel in a single-cylinder test engine under controlled conditions, adjusting compression and injection timing until the ignition performance matches that of reference fuels with known cetane numbers. This method is highly accurate, but it’s also time-consuming and costly. Labs that perform this test require skilled operators and precise instrumentation.

Because of the expense and complexity of the CFR test, many refineries and quality control labs also rely on calculated indexes, like the Cetane Index. These estimates use physical properties of the fuel—often density and distillation range—to predict cetane. ASTM D976 and ASTM D4737 are examples of standards that define how to calculate these indexes. While they don’t require an engine test, they might not perfectly capture the impact of additives or unusual feedstocks.

In practice, a company might do a direct CFR engine test on representative batches of diesel to confirm baseline quality. Then, they’ll run daily or hourly checks using the quicker calculated method to ensure the fuel stays within specifications. It’s a bit like checking one dish with a taste test (very hands-on) and then using a formula to gauge the quality of subsequent batches.

Why does this matter for you, the driver? If you’re in a region like the UK, fuels must meet standards such as EN 590, which dictate a minimum cetane number. Knowing that your diesel has been tested—either through direct engine methods or reliably correlated calculations—offers peace of mind that it won’t cause excessive knocking or emissions.

For those diving into the world of biodiesel or alternative fuels, these tests become even more important. The chemical composition might differ significantly from standard petroleum diesel, and the correlation formulas might not be as accurate if you have unusual compounds in your blend. In that case, going the extra mile with a CFR engine test can confirm whether you meet or exceed the necessary cetane requirements.

Regardless of how it’s measured, the cetane number is key to predicting how fuel will behave once it’s injected into a hot, compressed cylinder. A high number means quick ignition and less noise, a low number spells potential trouble. The fact that multiple methods exist allows producers to balance accuracy with practicality—ensuring that the fuel you pump into your tank is up to scratch without forcing every batch to undergo an expensive engine test.

This multi-tiered approach helps keep diesel uniform across different regions and suppliers, so you don’t end up with drastically varying quality every time you fill up. It’s all part of a broader system to ensure vehicles run well and comply with emission regulations. So whether you’re topping off your tank in a small town or a bustling city, you can be fairly confident in what you’re getting, thanks to the layered testing of cetane number.

At the end of the day, CFR engine tests remain the definitive measure—if you really need to know the precise ignition quality of a specific diesel, that’s the route you’d take. For general commercial purposes, though, the faster, calculation-based methods get the job done, especially when used in tandem with occasional engine tests for calibration. Either way, measuring cetane number is how the industry ensures your diesel meets the demands of modern engines with minimal fuss.

ASTM standardscetane measurementCFR methoddiesel ignition testfuel qualityUK regulations

Knowledge base

  • Carbon Cleaning FAQ
  • Cetane/2-EHN FAQ
  • Disesel Cleaners FAQ
  • DPF FAQ
  • E10 Petrol FAQ
  • EGR Valves FAQ
  • Engine Break-in FAQ
  • Exhaust Emissions FAQ
  • Friction Modifiers FAQ
  • Fuel Consumption FAQ
  • MAF Sensors FAQ
  • Oil Additives FAQ

Archives

  • September 2025
  • August 2025
  • July 2025
  • January 2025
  • December 2024
  • October 2024
  • September 2024
  • August 2024
  • July 2024
  • June 2024
  • May 2024
  • April 2024

Tag Cloud

Contact us

Email: support@fueltechexperts.com

Info
  • Privacy Policy
  • Terms of Use
  • Sitemap
  • Cookie Policy (UK)
  • https://ec.europa.eu/consumers/odr

Find us on:

Newsletter

* indicates required


Copyright © 2011-2024 Fuel Tech Experts All Rights Reserved.

Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}